TM 5-4220-231-14&P
b.
Replace
(1)
Lubricate
two new
O-rings
(3),
M83248/2-111,
with silicone compound
(Item 9, Appendix
D).
(2)
Place a lubricated
O-ring (3) over the
threads of
either tee (6) or adapter
(5)
at panel
as appropriate.
(3)
Position
and tighten
flexhose
(1) to
appropriate
fitting at panel by position-
PANEL
ing a wrench
on union nut (4) and
either tee (6) or adapter
(5).
Turn
union nut (4) clockwise.
6
4,3
5
(4)
Place
lubricated
O-ring
(3) over
threads
of appropriate
elbow
on
volume
tank.
(5)
Position
and tighten
flexhose
(1) to
appropriate
elbow on volumetank
by
203
positioning
a wrench
on elbow
and
VOLUME
union nut (2).
Turn union nut (2)
TANK
clockwise.
(6)
Apply pressure
to volume
tank.
Leak-
test with nonionic
detergent
(NID), GP
(Item 17, Appendix
D). Correct
leaks
as necessary.
(7)
Complete
Reentry
Control
Report
and
Log.