TM 5-4220-231-14&P
TROUBLESHOOTING - (Con't)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE
ACTION
Open isolation valve.
If HP IN gage on the DACC still does not register the same pressure
as the HP gage on the
DASS, the HP IN gage on the DACC is faulty.
Replace
HP IN gage.
If the HP IN gage indicates
normal operating
pressure,
go to Step 3.
Step 3. Open regulator 1/4 turn and read LP OUT gage on primary side of DACC.
Ensure that LP
OUT gage
isolation valve on DACC is open.
Open isolation valve.
If LP OUT gage does not function, either the regulator
is faulty or the LP OUT gage is
faulty
.
Go to Step
4.
Step
4.
To test
LP OUT gage
on the DACC, open
LP OUT supply
valve
and read
LP pressure
gage
on VTA
panel.
If LP gage
on the VTA panel
indicates
pressure,
and LP OUT gage
on DACC still indicates
no pressure,
LP OUT gage
on DACC is faulty.
Replace
LP OUT gage.
If gage
on VTA does
not register
pressure,
the regulator
on DACC is faulty.
Request
intermediate
direct support.
If LP gage
indicates
normal
operating
pressure,
go to Step
5.
Step
5.
Open
LP OUT valve on the DACC Primary
HP Supply
side.
Step
6.
Check
pressure
reading
of the LP pressure
gage on the VTA panel.
Gage
should
register
the
same
pressure
as LP OUT gage
on DACC.
If not, the LP OUT valve is faulty.
Request
intermediate
direct support.
Check
supply
hoses
from the DACC to the VTA for kinks or clogs.
Straighten
and clear
hoses.
3-11