TM 5-4220-231-14&P
TROUBLESHOOTING - (Con't)
MALFUNCTION
TEST
INSPECTION
CORRECTIVE
ACTION
Step
4.
Check
the
primary
HP IN valve
to ensure
it is open.
Open
primary
HP IN valve.
Step
5.
Open
Primary
HP Regulator
1/4 turn and
read
LP OUT gage.
If LP OUT gage
still indicates
below
normal
operating
pressure,
open
secondary
HP IN valve
and open
the
Secondary
HP
Regulator
1/4 turn.
If LP OUT gage
registers
correct
pressure,
the
problem
is in the
primary
circuit
of the CRS.
Either
the
HP IN valve
is faulty or the
regulator
is faulty.
Request
intermediate
direct
support.
If LP OUT gage
still reads
below
normal,
observe
LP OUT gage
on recompression
chamber.
If pressure
reaches
the chamber
but does
not register
on the CRS
LP OUT gage,
the CRS
LP OUT gage
is faulty.
Replace
the CRS
LP OUT gage.
If pressure
does
not reach
the chamber,
and
the LP OUT gage
on the CRS
does
not register
pressure,
problems
may exist
in both
primary
and
secondary
circuit
of the
CRS.
Either
the
Primary
and
Secondary
HP IN valves
are faulty,
or the
regulators
are
faulty.
Request
intermediate
direct
support.
5.
PRESSURE
GAGE
IS LEAKING.
Visually
inspect
gage
to confirm
that the gage,
not the connections
are
leaking.
Replace
gage.
6.
SUPPLY
VALVE
INOPERATIVE.
Step
1.
Cycle
valve
open
and
closed.
Step
2.
Note if the
valve stem
is turning
with the
handle.
If handle
is loose
on valve
stem,
tighten
handle
securing
screw.
If valve
stem
is stripped,
or cycling
does
not correct
the problem,
request
intermediate
direct
support.
3-14