TM 5-4220-231-14&P
TROUBLESHOOTING
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE
ACTION
1. PRESSURE
LOSS AT DIVER SUPPLY
HOSE.
Step
1. Check
the LP gage
on VTA panel.
If the gage
reading
is at normal operating
pressure,
the
malfunction
is downstream
of the gage.
Go to Step
2.
Step 2. Check
red, yellow, and green
diver supply
valves
on VTA to ensure
they are open.
Open valves.
If gage
indicates
below normal operating
pressure,
check
supply
hoses
for kinks or
crimps.
Straighten
hoses.
If no blockage
or kinks are found, supply
valves
are faulty or clogged.
Request
intermediate
direct support
If gage still reads
lower than normal operating
pressure,
pressure
is not getting to VTA.
Go to Step
3.
Step 3. Check
HP IN gage on DACC.
If HP IN gage
indicates
lower than normal operating
pressure,
ensure
gage
isolation
valve
is open.
Open
isolation
valve.
If HP IN gage still indicates
lower than
normal operating
pressure,
HP air is not getting to
DACC.
Go to Step
5.
If HP IN gage on the DACC shows
normal operating
pressure,
the problem
is downstream
of the gage.
Open
crossover
valve on DACC to charge
secondary
air supply
side of DACC.
If malfunction
is corrected,
the problem
is in the primary side of DACC.
Perform
the troubleshooting
steps
for malfunction
#2 of this section
(DACC Primary
Air Supply
Malfunction).
3-9