TM 5-4220-231-14&P
Change 7 3-3
Table 3-1 Unit Level PMCS Schedule.
H-Hourly M-Monthly Q-Quarterly A-Annually
ITEM
INTERVAL
ITEM TO BE
PROCEDURE
Equipment is Not
NO
H
M
Q
A
INSPECTED
Ready/Available if:
1
°
Diver Air Control
Console (DACC)
Inspect frame for broken or
damaged welds, dents, or other
damage.
Damage prevents
normal or safe
operation.
°
Inspect for missing or loose
nuts, bolts, and fasteners.
Check for loose or damaged
interconnecting piping, fittings,
and hoses.
°
Clean and preserve console.
2
°
Filter, HP U281
Request general support to clean
and inspect filter assembly.
Request general support replace
filter element as required.
3
°
Regulator, HP
Operate regulator through
turning arc.
Regulator jams or
operates
sporadically.
4
°
Valves
Turn each valve through a
complete open and close cycle.
Valve is jammed,
broken, or does not
perform function.
°
Clean and inspect exterior of
valve assemblies. Lubricate
valve stems.
5
°Gages
Calibrate IAW TB 9-4220-215-35
& TB 9-4220-216-35.
Expired calibration due
date
NOTE
Calibrate every 540 days or
whenever inaccuracies are
noted.