TM 5-4220-231-14&P
d.
EP-4
Sudden drop in any DASS Flask Pressure Gage (AHP-G211):
A.
PRIMARY DASS.
(1) Close DACC HP IN PRIMARY (AHP-V405) to isolate the problem.
(2) Open DACC HP IN SECONDARY (AHP-V401).
(3) Abort dive. Recover divers.
B.
SECONDARY
DASS.
(1) Close DACC HP IN SECONDARY (AHP-V401) to isolate the problem.
(2) Abort dive. Recover divers.
NOTE
Ifpressure drops on one flask pressure gage, it should drop on all
gages
within that system
because
they are all connected
by
interconnecting
hoses.
CHAMBER
e.
EP-5
Sudden
drop of LP OUT Pressure
Gage
VTA (ALP-G616):
(1) Open PRIMARY HP IN (AHP-V601).
(2)
Disengage
compressors.
(3)
Consult
with Diving Medical Officer for options for continuation
of treatment.
2-82
Change