TM 5-4220-231-14&P
2-1 b. Volume Tank Assembly (VTA)Control Panel and Indicators (Refer to Figure 2-2).
INDEX
NAME
ID
POSITION
FUNCTION
1
VOLUME TANK
NORMAUCLOSED
ACTIVATES
IF VOLUME
RELIEF VALVE
TANK PRESSURE
EXCEEDS
275 PSIG
2
RED DIVER AIR
ALPV505
OPEN CCW
CONTROLS
FLOW OF
SUPPLY
BREATHING
AIR TO RED
DIVER
3
GREEN
DIVER AIR
ALPV506
OPEN CCW
CONTROLS
FLOW OF
SUPPLY
BREATHING
AIR TO GREEN
DIVER
4
YELLOW DIVER
ALPV507
OPEN CCW
CONTROLS
FLOW OF
AIR SUPPLY
BREATHING
AIR TO
YELLOW DIVER
5
BLEED VALVE
ALPV508
OPEN CCW
ALLOWS PRESSURE
TO BE
BLED FROM VOLUME TANK
CONTROLPANEL
6
GAGE
ISOLATION
ALPV509
OPEN CCW
ACTIVATES
LP SUPPLY
AIR
DIVER SUPPLY
TO DIVER SUPPLY
PRESSURE
PRESSURE
GAGE
7
DIVER SUPPLY
ALPG51 0
0 - 500 PSIG
INDICATES
LP AIR BEING
PRESSURE
SUPPLIED
FROM THE
VOLUME TANK TO DIVERS
VOLUME TANK
OPEN CCW
DRAINS CONDENSATE
Lij
DRAIN
FROM
VOLUME TANK
Change
2
2-7