TM5-4220-231-14&P
2-1 c. Diver AirStorage System (DASS) Controls and Indicators(Refer to Figure 2-3).
INDEX
NAME
ID
POSITION
FUNCTION
1
FLASK VALVES
OPEN CCW
ALLOWS HP AIR TO FLOW
FROM FLASK TO SUPPLY
OUT VALVE, GAGE
ISOLATION VALVE, AND
FLASK SUPPLY PRESSURE
GAGE
2
FLASK PRESSURE
AHPG211
0 - 6000 PSIG
INDICATE TOTAL FLASK
GAGE
RACK PRESSURE
3
SUPPLY
OUT
AHPV203
OPEN CCW
ALLOWS HP AIR TO FLOW
VALVE
TO NEXT RACK OR TO THE
DIVER AIR CONTROL
CONSOLE
4
SUPPLY
IN VALVE
AHPV204
OPEN CCW
ALLOWS HP AIR TO BE
SUPPLIED
FROM THE
OUTLET
FROM ANOTHER
FLASK RACK
5
GAGE
ISOLATION
AHPV205
OPEN CCW
ACTIVATES
FLASK SUPPLY
FLASK PRESSURE
PRESSURE
GAGE
6
CHARGE
INLET
AHPV208
OPEN CCW
ALLOWS HP AIR TO BE
VALVE
SUPPLIED
TO THE FLASKS
FROM THE HP
COMPRESSOR
7
CHARGE
OUTLET
AHPV209
OPEN CCW
ALLOWS HP AIR TO BE
VALVE
DISCHARGED
FROM THE
FLASKS
8
BLEED VALVE
AHPV210
OPEN CCW
ALLOWS AIR TO BE BLED
FROM THE DASS RACK
9
PRESSURE
STATIONARY
AUTOMATICALLY
VENTS
RELIEF VALVE
FLASKS
IN THE EVENT OF
OVER PRESSURE
TEMPERATURE
STATIONARY
AUTOMATICALLY
VENTS
RELIEF VALVE
FLASKS
IN THEEVENT
OF
EXCESSIVE
TEMPERATURE
Change 4