TM 5-4220-231-14&P
2-1 d. Chamber Reducing Station (CRS) Controls and Indicators (Refer to Figure 2-4).
INDEX
NAME
ID
POSITION
FUNCTION
1
PRIMARY
HP IN
AHPV601
OPEN
CCW
ALLOWS
HP AIR TO BE
SUPPLIED
FROM THE
DASS
TO PRIMARY
REGULATOR
AND THE
DOME
LOADER
2
SECONDARY
HP
AHPV606
OPEN
CCW
ALLOWS
HP AIR TO BE
IN
SUPPLIED
FROM THE
DASS
TO SECONDARY
REGULATOR
3
LP IN PRIMARY
ALPV612
OPEN
CCW
ALLOWS
LP AIR TO FLOW
SUPPLY
FROM PRIMARY
LP
COMPRESSOR
STORAGE
TANK
4
LP IN
ALPV613
OPEN
CCW
ALLOWS
LP AIR TO FLOW
SECONDARY
FROM SECONDARY
LP
SUPPLY
COMPRESSOR
STORAGE
TANK
5
LP SUPPLY
OUT
ALPV61
0
OPEN
CCW
ACTIVATES
FLOW OF
BREATHING
AIR TO
RECOMPRESSION
CHAMBER
6
PRIMARY
HP
AHPV602
INCREASE
LP-CW
HANDLOADED
REGULATOR
DECREASE
LP-CCW
REGULATOR
WHICH
REDUCES
PRIMARY
HP AIR
TO DESIRED
OPERATING
LP PILOT AIR TO THE
DOME
LOADER
7
SECONDARY
HP
AHPV607
INCREASE
LP-CW
HANDLOADED
REGULATOR
DECREASE
LP-CCW
REGULATOR
WHICH
REDUCES
SECONDARY
HP
AIR TO DESIRED
OPERATING
LP
8
HP IN GAGE
AHPG615
0 - 6000
PSIG
INDICATES
HP AIR SUPPLY
FROM THE AIR STORAGE
UNIT
9
LP OUT GAGE
ALPG616
0 - 500 PSIG
INDICATES
LP AIR BEING
SUPPLIED
TO MANIFOLD
10
BLEED
VALVE
ALPV608
OPEN
CCW
ALLOWS
LP AIR PRESSURE
BE BLED OFF
FROM
THE CRS
Change 2
2-11