TM 5-4220-231-14&P
2-1 a. Diver AirControl Console (DACC) Controls and Indicators(Refer to Figure 2-1).
INDEX
NAME
ID#
POSITION
FUNCTION
1
HP REGULATOR
AHPV406
INCREASE
LP-CW
HAND LOADED
PRIMARY HP
DECREASE
LP-CCW
REGULATOR
WHICH
SUPPLY
REDUCES
HP AIR TO
DESIRED OPERATING
LP
2
HP REGULATOR
AHPV402
INCREASE LP-CW
HAND LOADED
SECONDARY
HP
DECREASE
LP-CCW
REGULATOR
WHICH
SUPPLY
REDUCES
HP AIR TO
DESIRED OPERATING
LP
3
HP IN PRIMARY
AHPV405
OPEN CCW
CONTROLS
FLOW OF HP
HP SUPPLY
AIR TO THE PRIMARY AIR
SUPPLY
4
HP IN
AHPV401
OPEN CCW
CONTROLS
FLOW OF HP
SECONDARY
HP
AIR TO THE SECONDARY
SUPPLY
AIR SUPPLY
5
LP OUTLET
ALPV412
OPEN CCW
CONTROLS
FLOW OF
PRIMARY LP
PRIMARY LP AIR TO THE
SUPPLY
VOLUME TANK
6
LP OUTLET
ALPV411
OPEN CCW
CONTROLS
FLOW OF
SECONDARYLP
SECONDARY
LP AIR TO
SUPPLY
THE VOLUME TANK
7
LP INLET
ALPV41 0
OPEN CCW
CONTROLS
FLOW OF LP
AIR TO THE VOLUME TANK
FROM 88.5 CFM LP
COMPRESSOR
8
GAGE ISOLATION
AHPV407
OPEN CCW
ACTIVATES THE PRIMARY
HP IN PRIMARY
REGULATOR
HP SUPPLY
HP SUPPLY
GAGE
9
GAGE ISOLATION
ALPV408
OPEN CCW
ACTIVATES THE PRIMARY
LP OUT PRIMARY
REGULATOR
LP SUPPLY
HP SUPPLY
GAGE
10
HP CROSS-OVER
AHPV409
OPEN CCW
ACTIVATES SECONDARY
HP SUPPLY
11
GAGE ISOLATION
ALPV414
OPEN CCW
ACTIVATES THE CONSOLE
CONSOLE
PRESSUREGAGE
PRESSURE
12
GAGE ISOLATION
ALPV404
OPEN CCW
ACTIVATES THE
LP OUT
SECONDARY
REGULATOR
SECONDARY
HP
LP SUPPLY GAGE
SUPPLY
Change
2
2-3