TM54220-231-14&P
(2)
Lubricate new O-ring (6), M83248/2-
912, with silicone compound
(Item 9,
Dome
Loaded
Appendix
D).
Place
O-ring
over
Regulator
threads
on filter. Install filter in dome
loaded
regulator.
6
(3)
Lubricate
new O-ring (8), M83248/2-
212, with silicone compound
(Item 9,
Appendix
D). Install O-ring in O-ring
groove
on end fitting of tube (4).
Position and tighten tube (4)
to
threaded
connector
(2) by tightening
union nut (3) to connector
(2). Turn
union nut clockwise.
2
8
3
4
(4)
Lubricate
new O-ring (9), M83248/2-
212,
with silicone compound
(Item
9, Appendix
D) and place O-ring in
O-ring groove
in end fitting of tee
(11). Position and tighten tube (4) to
4
tee (11) by tightening
union nut (5)
clockwise.
(5)
Apply pressure
to CRS.
Leak-test
with
nonionic
detergent
solution
(NID) GP (Item 17, Appendix D).
Correct leaks as necessary.
(6)
Complete
Reentry
Control
Report
and Log.
@2
5
9
4-101