TM 5-4220-231-14&P
(3)
Lubricate new O-ring (6), M83248/2-
210, with silicone
compound
(Item 9,
Appendix
D), and
install
in O-ring
groove
in end of tube
(8).
(4)
Position
and tighten
tube
(8) to valve
(5) by positioning
a wrench
on union
5
nut (7) and turning
nut clockwise.
6
7
8
(5)
Lubricate
new O-ring (9), M83248/2-
210, with silicone
compound
(Item 9,
Appendix
D), and
install
in O-ring
10
groove
in end of tube
(11).
(6)
Position
and
tighten
tube
(11) to
9
valve (5) by positioning
a wrench
on
5
union
nut
(10)
and
turning
nut
clockwise.
(7)
Apply
pressure
to CRS.
Leak-test
with
nonionic
detergent
solution
(NID) GP
(Item
17, Appendix
D).
Correct
leaks
as necessary.
(8)
Complete
Reentry
Control
Report
and
Log.
5
9
4-110