TM 5-4220-231-14&P
b. 
Replace
(1)
Remove 
the   following 
parts    from    the
new    high    pressure 
regulator 
housing
(8):
hex    head     screw     (1),    center
8
spacer 
(2),   three     hex   head    screws
(3),  handle   (4),  bushing    (5),  neoprene
sleeve     (6),  and   hex   nut   (7).    Retain
6
7
all  removed 
parts.
4
5
2
(2)
Lubricate 
new     O-ring     (17),    (21),
17
M83248/2-908, 
M83248/2-210 
with
13
silicone     compound 
(Item   9,  Appendix
D)  and    place    on    positionable 
union
8
21
12
20
(3)
Install   filter   (12),    with  tailpiece 
(20)
and   positionable 
union   (13)   attached,
to   regulator 
housing     (8)   by   turning
union   clockwise.
9
16
(4)
Lubricate 
new   O-ring    (16),   M83248/2-
908,    with   silicone    compound 
(Item   9,
Appendix
D),
and
place 
on
positionable 
elbow 
(9).
Install
positionable 
elbow     (9)   in   regulator
8
housing
(8)
by 
turning 
elbow
12
clockwise. 
Position 
elbow    correctly
20
and    finger-tighten 
nut.
(5)
Carefully 
position 
housing 
through
opening 
from    back    of  panel.
4-84