TM 5-4220-231-14&P
g.
REMINDER:
For Department
of Transportation
(DOT) specification
and exception,
the cylinder
certification
date starts when the manufacturer
hydrostatically
tests a cylinder and marks that date as the date
of manufacture.
The time between
hydrostatic
test is the actual time elapsed
from the date on the cylinder.
h. STORE
FLASKS OUT OF THE WEATHER.
3-35
Transportation
Limitations.
Due
to temperature
restrictions
of the
SDASS
equipment
and
the
necessity
of maintaining
an airtight
system,
the following
limitations
and conditions
must
be observed
during
transportation.
a.
Do not use
a forklift to move
subassemblies
under
any circumstances.
b.
DASS
racks
must
be lashed
together
when
stacked
for transportation
in any mode.
c. Local state
and federal
regulations
will be followed
when the SDASS
is transported
by air, rail, water
or ground
modes.
d.
All subassemblies
will be properly
secured
during
shipment
by any mode
to avoid
shifting
which
could cause
damage
to the equipment.
e. After transporting
the SDASS
check
all connectors,
fittings,
pipes,
gages,
valves,
etc. for looseness
or damage
IAW PMCS
tables
"Before"
checks.
Tighten
and/or
repair
as required.
3-36
Depreservation
Of The High Pressure
Composite
Air Flasks.
a.
To return
the air flasks
to service
after
storage,
vent
the flasks
of the fry nitrogen.
b. Check
the technical
manual
for the system
and perform
any maintenance
that is required
according
to the Preventive
Maintenance
Checks
and Services
section.
c.
Pressurize
the flasks
with diver's
air, from an authorized
source,
to approximately
100 psi.
d.
Vent the flasks
to 0 psi, to purge
them
of any remaining
nitrogen.
e.
Pressurize
the flasks
with diver's
air, from an authorized
source,
to a minimum
of 600 psi up to the
maximum
pressure
of 5000
psi.
f. Take
an air purity
sample.
If the sample
meets
purity standards
in NAVSEA 0994-LP-001
-9110
(US Navy
Diving Manual
Volume
1), the
system
is ready
for diving.
If the
sample
does
not meet
purity
standards,
inspect
the flasks
according
to the instructions
in the technical
manual.
Change
3
3-51/(3-52
blank)