TM 3-4240-212-14&P
CHAPTER 5
DIRECT SUPPORT MAINTENANCE
Section I. FACEPIECE GROUP
(2) Slide housing clamp over facepiece opening.
5-1.
Valve Assembly, Facepiece
(3) Install facepiece valve assembly in facepiece
a. Removal
opening. The inlet branch containing pressure relief valve
(1) Disconnect breathing tubes from facepiece
must be at right side of facepiece. Stretch rubber
facepiece to seat facepiece valve assembly.
(4) Install washer and nut on facepiec valve
e
necessary, remove clamp. Take care not to distort it.
assembly.
Make sure rubber surrounding hole in
(3) Remove nut (3) and washer (4).
facepiece is held firmly between washer and flange on
(4) Work rubber faceblank (2) from around
valve assembly.
facepiece valve assembly. Separate valve assembly
(5) Tighten housing clamp. Take care not to
from facepiece.
distort clamp or damage facepiece.
(5) Remove housing clamp from facepiece.
b. Testing Inhalation Check Valve.
(1) Blow into inlet branch of facepiece valve
5-2. Faceblank
assembly Air should pass freely through inlet branch.
a. Removal.
(2) Try to draw air from inlet branch. Inhalation
check valve should close with an audible click and
prevent air passage.
(2) through (5)).
(3) If inhalation check valve does not operate
(2) Unfasten head-harness straps and remove
properly, install a new facepiece valve assembly.
harness.
c. Testing Exhalation Check Value.
(1) Try to draw air from outlet branch of facepiece
b. Installation.
valve assembly. Air should pass freely.
(1) Install lenses and lens clamps in a new
(2) Blow air into outlet branch. The exhalation
check valve should close and prevent air passage.
(3) If exhalation check valve does not operate
(3) Install facepiece valve assembly in faceblank
properly, install a new facepiece valve assembly.
d Installation.
(1) Moisten inside of facepiece opening with
water. Do not use oil.
Section II. BACKPLATE ASSEMBLY
(2) Pass screw (18) through lower hole in
5-3.
Waist-Strap Eyes
waiststrap eye and through hole in guard and backplate.
a. Removal.
(3) Install nuts (16) and tighten.
(1) Unhook harness snaphooks from waiststrap
(4) Attach snaphooks on harness straps to
waiststrap eyes.
(2) Remove screws (18 and 19) and nuts (16)
that fasten waist-strap eyes to guard and backplate
5-4.
Breathing Bag
assembly (13).
a. Removal.
b. Installation.
(1) Loosen hose clamps (2, fig. B-2) attaching
(1) Pass screw (19) through upper hole in waist-
breathing bag tubes to plunger valve (10) and to
strap eye, through hole in guard and backplate, and
inhalation elbow (6) by lifting latches
through eyelet in tab on breathing bag.
5-1