TM 5-4220-225-14
Table 3-1. Operator Troubleshooting Procedures.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. REDUCED AIR FLOW
Step 1. Check air supply valve.
Adjust air supply valve.
Step 2. Check exhaust valve.
Adjust exhaust valve.
Step 3. Check air whip connection.
Tighten loose connection.
2. UNABLE TO INCREASE AIR FLOW.
Step 1. Check air supply valve.
Adjust air supply valve.
Step 2. Check exhaust valve.
Adjust exhaust valve.
Step 3. Check air whip connection.
Tighten loose connection.
SECTION III. OPERATOR MAINTENANCE PROCEDURES
This section is not applicable.
3-2