TM 54220-231-14&P
b.
Replace
(1)
Lubricate now O-ring (4) and now
backup ring (3) (all of which are in
the soft goods
kit) with silicone
compound
(Item 9, Appendix
D).
Install backup ring (3) and O-ring (4)
on valve.
(2)
Install valve (1) in manifold (2) by
turning counterclockwise
(Valve has
left hand threads).
(3)
Apply pressure
to CRS.
Leak-tee
with nonionic detergent
solution (NID)
GP (Item 17, Appendix D). Correct
leaks as necessary.
(4)
Complete
Reentry
Control
Report
and Log.
4-92