TM6-4220-231-14&P
(9)
Lubricate
new O-rings (15, 16),
M83248/2-111,
with
silicone
14
compound
(Item 9, Appendix
D).
15
Place
O-ring (16) over threads
of
positionable
elbow
(13 and
14).
13.16
Tighten hard tube (9) to elbow (13)
by positioning
a wrench on union nut
(11)
and
turning
nut
clockwise.
Tighten
hard tube (10) to positionable,
10
elbow (14) by positioning a wrench
12
11
on
union
nut
(12) and
turning
9
clockwise.
(10) Lubricate
new
O-rings
(4,
8),
4
M83248/2-111,
with
silicone
3
compound
(Item 9, Appendix D), and
install over threads
of positionable
7,8
elbows (7, 3).
Tighten flexible line
(5) to elbow (7) by positioning a
wrench on union nut (6) and turning
clockwise.
Tighten flexible line (1) to
elbow (3) by positioning a wrench on
2
6
union nut (2) and turning clockwise.
5
(11) Apply
pressure
to
volume
tank.
Leak-test
with
nonionic
detergent
solution (NID) GP (Item 17, Appendix
D). Correct leaks as necessary.
(12) Complete Reentry Control Report
and Log.
1
@21'
@@7
'8
1
?2
6
4-47