22-8 Change A
U.S. Navy Diving ManualVolume 5
22-2.5.1
Labeling. All lines should be identified and labeled to indicate function, content
and direction of flow. The color coding in Table 22-1 should be used.
22-2.5.2
Inlet and Exhaust Ports. Optimum chamber ventilation requires separation of the
inlet and exhaust ports within the chamber. Exhaust ports must be provided with a
guard device to prevent accidental injury when they are open.
Height
52.9
Width
54.8
Weight
1,367 lbs.
Internal Volume
45.5 cu. ft.
Door Opening
2 doors 26
View Ports
2 @ 6 dia. Clear Opening
Mating Flange
Rotating Female per NATO STANG
1079
Life Support Scrubber
Air-driven, replaceable scrubber,
canister fits in TRC Med Lock
BIBS
2 masks oxygen and air supply
overboard dump
Design Pressure
110 psig
Atmospheric Monitoring
Oxygen and Carbon Dioxide Analyzer
Design Temperature
0-125°F
Gas Supply
Primary and secondary air and O2
Length
69.9
Communications
Sound-powered phone
Figure 22-7. Transfer Lock (TL).
Figure 22-8. Fly Away Recompression Chamber (FARCC).