TM 5-4220-231-14&P
(4)
Lubricate new O-ring (10), M83248/2-
010, with silicone compound
(Item 9,
Appendix
D), and install over the
threads
of positionable
elbow (8).
Position and tighten tubing (12) on
positionable, elbow (8) by tightening
union nut (111).
12
Vj
8
(5)
Lubricate new O-ring (7), M83248/2-
010, with silicone compound
(Item 9,
Appendix
D), and install on threaded
5
fitting on valve (4).
Position and
4@6
tighten tubing (5) to valve (4) by
C>"'- 7
turning union nut (6) clockwise.
4
(6)
Apply pressure
to DAM
Leak-test
with nonionic detergent
solution (NID)
GP (Item 17, Appendix D). Correct
leaks as necessary.
(7)
Reinstall and secure the DACC panel
in the DACC case
with all securing
screws.
Replace
and secure
case
front cover over DACC panel.
(8)
Complete
Reentry
Control
Report
and Log.
4-37