TM 5-4220-225-14solution to all segments of the pipe. If you run out of cleaning solution prior to the 30 minutes listed, prepareanother volume of cleaning solution.Table 4-4. Cleaning Solution Flow Rate.Tube Size (inches)GPMPipe Size (inches)GPM1/4 (0.6 cm)1/21/4 (0.6 cm)23/8 (1.0 cm)23/8 (1.0 cm)31/2 (1.3 cm)3 3/4½ (1.3cm)5 1/23/4 (1.9 cm)6 3/43/4 (1.9 cm)9 1/21 (2.5 cm)12 1/21 (2.5 cm)15 1/21 1/4 (3.1 cm)231 1/2 (3.8 cm)352 (5.1 cm)50(5) Pump hot distilled or deionized water through the system to rinse until all visible traces of cleaningsolution are removed.(6) Draw 10 mL sample. Agitate to observe for soap bubbles. If any soap bubbles are present, repeatstep (5) until no bubbles are observed.(7) Blow dry parts or components with clean, dry, oil-free nitrogen (preferably heated to 200 degrees F(93.3 degrees C)) until all visible signs of water are absent. Maintain process for 1 to 2 hours afterinitial purge.(8) Double bag and seal or tape closed all components and ends of pipe or hoses with plastic until readyfor reinstallation.c. Hoses shall be cleaned as specified in paragraph 4-38.4-41. Cleaning Component Soft Goods. The following isopropyl alcohol method is provided for the cleaning of thesoft goods and aluminum parts of system components. The method for non-ionic detergent is the same procedure asthat in paragraph 4-38.CAUTIONEnsure ventilation is adequate and avoid breathing vapors.4-96