Dome     Loaded Regulator (CRS).
Remove bolts

TM-5-4220-231-14P Recompression Chamber 3-Person Model RC-100-2 Serial Numbers 08-A-163 Thru 08-A-172 Manual
Page Navigation
  227    228    229    230    231  232  233    234    235    236    237  
TM 5-4220-231-14&P (3) Loosen tube (7) from positionable elbow (2)   by   positioning a   wrench on union nut (3) and turning counter- clockwise. Remove, cut,    and    discard O-ring    (10). 2 7 3,10 (4) Remove tube (5)   between the   dome loaded regulator and the primary 5 6,8 regulator by   positioning a   wrench on the   union    nut  (6)  on   each end   of  tube (5)    and turning union counterclock- wise, as    shown. Remove, cut,    and discard O-ring    (8)   at  each end. (5) Remove adapter (4)    from regulator (1)   by positioning a   wrench on    the 4,9 nut and turning counterclockwise. Remove, cut,   and discard O-ring (9). (6) Remove the two    hex socket bolts, which are installed through the flat support to   the    regulator, from   the    top of   the regulator. Replace both bolts in  top   of   regulator. '9 4-87