Complete Reentry Control Report and    Log. - TM-5-4220-231-14P_207
Remove relief    valve

TM-5-4220-231-14P Recompression Chamber 3-Person Model RC-100-2 Serial Numbers 08-A-163 Thru 08-A-172 Manual
Page Navigation
  178    179    180    181    182  183  184    185    186    187    188  
TM  5-4220-231-14&P 4-12    Relief    Valve   (DACC). This   task   covers: Replace INITIAL  SETUP Tools Equipment Conditions General     Mechanics Tool   Kit Rermove front   cover    trom   DACC   case    (Para    3-15    1-2) O-ring   Installation and   Removal Tool Remove     rear   DACC   panel    (Para   3-15   3) Materials/Part References Valve,    Relief    13229E4600 Para    4-2,   General O-ring,    M83248/2-010 (2) O-ring,    M83248/2-904 (1) Silicone    Compound (Item   9,  Appendix D) Tape,    Teflon   (Item   19,  Appendix     D) Nonionic    Detergent Solution    (NID)   GP, (Item   17,  Appendix    D) a. Remove (1) Determine location     of  the    relief   valve. (2) Remove    tube    (2)   from   valve    (1)   by positioning a  wrench    on   union    nut   (3). Turn    union     nut    counterclockwise. RELIEF Remove, cut,   and    discard O-ring    (4) VALVE from  valve   fitting   groove. 2 3,4 1 RELIEF@d VALVE 4-38 Change 1