High    Pressure (HP)   Supply Valve    (DACC).
Install   positionable elbow   

TM-5-4220-231-14P Recompression Chamber 3-Person Model RC-100-2 Serial Numbers 08-A-163 Thru 08-A-172 Manual
Page Navigation
  156    157    158    159    160  161  162    163    164    165    166  
TM   6-4220-231-14&P (3) Remove tube (12)    from    positionable elbow (8)   by   positioning a  wrench on both   union   nut   (11)   and   elbow    (8) 8 and turning union nut counter- 11,10 clockwise. Remove, cut,   and   discard 12 O-ring   (10). (4) Use   an   alien   wrench to   loosen    set 2 screw    (2).    Remove    valve   handle    (1) from   stem   of valve    (4).   Remove hex 3 nut  (3)  from   valve. 4 (5) Remove    valve   (4)  with  elbow   (8)  from panel. Remove positionable elbow (8)    from valve by positioning a wrench on   the   nut   and    loosening it by 9 4 turning clockwise and   unscrewing the elbow from   the   valve. Remove, cut, and   discard O-ring    (9). 8 4-16